en English
en English af Afrikaanssq Albanianam Amharicar Arabicfr Frenches Spanishru Russiande Germanhy Armenianit Italianja Japaneseko Koreanpt Portuguesehi Hindiaz Azerbaijaniro Romanianpl Polishth Thaiel Greekeu Basquezh-CN Chinese (Simplified)zh-TW Chinese (Traditional)be Belarusianbn Bengalibs Bosnianbg Bulgarianca Catalanceb Cebuanony Chichewaco Corsicanhr Croatiancs Czechda Danishnl Dutcheo Esperantoet Estoniantl Filipinofi Finnishfy Frisiangl Galicianka Georgiangu Gujaratiht Haitian Creoleha Hausahaw Hawaiianiw Hebrewhmn Hmonghu Hungarianis Icelandicig Igboid Indonesianga Irishjw Javanesekn Kannadakk Kazakhkm Khmerku Kurdish (Kurmanji)ky Kyrgyzlo Laola Latinlv Latvianlt Lithuanianlb Luxembourgishmk Macedonianmg Malagasyms Malayml Malayalammt Maltesemi Maorimr Marathimn Mongolianmy Myanmar (Burmese)ne Nepalino Norwegianps Pashtofa Persianpa Punjabism Samoangd Scottish Gaelicsr Serbianst Sesothosn Shonasd Sindhisi Sinhalask Slovaksl Slovenianso Somalisu Sudanesesw Swahilisv Swedishtg Tajikta Tamilte Telugutr Turkishuk Ukrainianur Urduuz Uzbekvi Vietnamesecy Welshxh Xhosayi Yiddishyo Yorubazu Zulu

+86-371-60997506 info@gv-medic.com

Facebook
Twitter
Youtube
LinkedIn
Pinterest

Gemc Technology Co.,Ltd
  • Home
  • About us
  • Products
    • Prenatal & Postnatal Care Test
    • Fertility Test
      • Pregnancy Test Kits
      • Digital Pregnancy Test
      • Ovulation Test Kits
      • Ovulation Microscope
      • Menopause Test Kits
    • Drug of Abuse Test
      • Urine Drug Abuse Test Device
      • Oral Fluid Drug Abuse Test Device
    • Infectious Disease Test
    • Tumor Marker Test Kits
    • Cardiac Marker Test
    • Bacterial Infection Test
    • Urinalysis Reagent Strip
    • pH Indicator
    • Blood Glocose Monitoring System
    • Water Test Paper
    • Pet Test kits
    • Food Safety Test
    • Lab Meters and Probes
      • TDS meter
      • ORP meter
      • Conductivity meter
    • Biochemistry Rapid Test
    • Sexually Transmitted Disease
  • News
    • Company news
    • Industry-news
  • Our Certificate
  • Feedback
  • Contact us
  • Get a quot
  1. Home
  2. Products
  3. Tumor Marker Test Kits
  4. (CEA) Carcinoembryonic Antigen Test Stri
  • (CEA) Carcinoembryonic Antigen Test Strip CEA-W01B

(CEA) Carcinoembryonic Antigen Test Strip CEA-W01B

  • Product Item:CEA-W01B
  • Type: Strip
  • Specimen: Whole Blood/Plasma/Serum
  • Package: Individual foil pouch
  • CEA Strip  , Carcinoembryonic strip test
    Inquiry Send Email
    Description

    Details

    Product Name

    Specimen

    Format

    Catalog No.

    Cut-off(ng/ml)

    Strip width

    (CEA)Carcinoembryonic Antigen Test

    Whole Blood/Serum/plasma

    Strip

    CEA-W02B

    5

    3.0mm

    Strip

    CEA-W02D

    5

    4.0mm

    INTRODUCTION
    One Step CEA Test Strip is a rapid direct binding test for the detection of carcinoembryonic antigen in  whole blood  as an a human tumor marker. The test is based on the principle of sandwich immunoassay for determination of CEA in whole blood.  Two monoclonal antibodies are employed to identity CEA specifically. This one step test is very sensitive and only takes about 10-15 minutes.  The sensitivity of the test can reach to 5ng/mL.

    PRINCIPLE
    The CEA Rapid Test Strip (Whole Blood/Serum/Plasma) detects human carcinoembryonic antigen (CEA) through visual interpretation of color development on the internal strip. CEA antibodies are immobilized on the test region of the membrane. During testing, the specimen reacts with CEA antibodies conjugated to colored particles and precoated onto the sample pad of the test. The mixture then migrates through the membrane by capillary action, and interacts with reagents on the membrane. If there are sufficient CEA antigens in the specimen, a colored band will form at the test region of the membrane. The presence of this colored band indicates a positive result, while its absence indicates a negative result. The appearance of a colored band at the control region serves as a procedural control, indicating that the proper volume of specimen has been added and membrane wicking has occurred.

    SPECIMEN COLLECTION
    For whole blood, collect blood into a container with anticoagulant. If the specimen cannot be tested on the day of collection, store the whole blood specimen in a refrigerator. Bring the specimens to room temperature before testing.

    TEST PROCEDURE
    1. When you are ready to begin testing, open the sealed pouch by tearing along the notch. Remove the test from the pouch and use it as soon as possible. Best results will be  obtained if the assay is performed within one hour.
    2. Place the test device on a clean and level surface. Be sure to label the device with specimen’s ID number.
    3. Add 50 ul of fresh blood to the Sample Well (for Card) or Sample Pad (for Dipstick),Then add 2 drops (50 ul) of test running buffer into the sample well or sample pad.
    4. Wait for the red line(s) to appear. The result should be read in 10-15 minutes. Do not read results after 30 minutes.

    INTERPRETATION OF RESULTS
    Negative: Only one colored band appears on the control (C) region. No apparent band on the test (T) region.
    Positive: In addition to a pink colored control (C) band, a distinct pink colored band will also appear in the test (T) region. This indicates an CEA concentration of more than 5ng/ml. If the test band is equal to or darker than the control band, it indicates that the CEA concentration of specimen has reached to or is greater than 100ng/ml. Please consult your physician to perform a much more detailed exam.
    Invalid: If without colored band appears at control region, this is an indication of a possible error in performing the test. The test should be repeated using a new one.

    STORAGE AND STABILITY
    The test kits can be stored at room temperature (2 to 30 C) in the sealed pouch to the date of expiration.  The test kits should be kept away from direct sunlight, moisture and heat.

    PRECAUTION
    1. For in vitro diagnostic use only.
    2. Do not use test kit beyond the expiry date.
    3. The test device should not be reused.



    Inquiry Us





    Related Products

    OPI-U01B OPI Opiate Test Strip

    OPI-U01B OPI Opiate Test Strip

    Ovulation Test Strip LH-U01C

    Ovulation Test Strip LH-U01C

    HIV Test Cassette HIV-W02B

    HIV Test Cassette HIV-W02B

    COT-S02M COT Cotinine Test Device

    COT-S02M COT Cotinine Test Device

    AMP-U01D Amphetamine Test Strip

    AMP-U01D Amphetamine Test Strip

    AMP-S02M (AMP) Amphetamine Test Cassette

    AMP-S02M (AMP) Amphetamine Test Cassette

    Categories

    • Prenatal & Postnatal Care Test
    • Fertility Test
      • Pregnancy Test Kits
      • Digital Pregnancy Test
      • Ovulation Test Kits
      • Ovulation Microscope
      • Menopause Test Kits
    • Drug of Abuse Test
      • Urine Drug Abuse Test Device
      • Oral Fluid Drug Abuse Test Device
    • Infectious Disease Test
    • Tumor Marker Test Kits
    • Cardiac Marker Test
    • Bacterial Infection Test
    • Urinalysis Reagent Strip
    • pH Indicator
    • Blood Glocose Monitoring System
    • Water Test Paper
    • Pet Test kits
    • Sexually Transmitted Disease
    • Food Safety Test
    • Lab Meters and Probes
      • TDS meter
      • ORP meter
      • Conductivity meter
    • Biochemistry Rapid Test

    Links

    Google.comGem MedicGemc Biotech

    COVID-19 (SARS-CoV-2) Antigen Test Kit manufacturer and supply from China

    LatestPost

    • We GEMC are back to office from Lunar New Year
      We GEMC are back to office from Lunar Ne
      2023-01-28
    • COVID-19 Neutralizing Antibody Test Kits are developed successfully
      COVID-19 Neutralizing Antibody Test Kits
      2021-02-27

    Feedback

    Contact Us

    153448046

    +8615838280034

    +86-371-60997506

    info@gv-medic.com

    shadowcrsg

    No.20, Bosong Rd, Zhengzhou City, Henan Province,China

    MOBILE WEBSITE

    Copyright © 2013-2023 Gemc Technology Group Limited & Gemc Technology Co.,Ltd All Rights Reserved.

    • Skype.
    • E-mail
    • Whatsapp
    • Inquiry